Changes between Version 2 and Version 3 of configure-hp-pro-curve


Ignore:
Timestamp:
Nov 3, 2012, 7:13:31 PM (7 years ago)
Author:
Jamie McClelland
Comment:

--

Legend:

Unmodified
Added
Removed
Modified
  • configure-hp-pro-curve

    v2 v3  
    2525
    2626After it restarts, you should re-connect via the new serial console settings
    27  * At this point, you might want to upgrade the firmware. Check the [http://www.hp.com/rnd/support/manuals/2800.htm HP page for the latest firmware]. Check the running firmware with:
     27 * At this point, you might want to upgrade the firmware. Check the [http://h17007.www1.hp.com/us/en/support/converter/index.aspx?productNum=J4903A HP page for the latest firmware]. Check the running firmware with:
    2828{{{
    2929show version
    3030}}}
     31As for 2012-11-3, the latest firmware on the site is i.10.77 built on 26-Aug-2009, posted on 26-Oct-2009.
     32 * To update the firmware:
     33  * Downloading the latest version to a machine connected to the switch
     34  * Install and start tftpd-hpa on the machine
     35  * On the server, type:
     36{{{menu}}}
     37  * Selected Download OS from the menu
     38  * Entered the IP address of the server and the remote file name (/srv/tftp/I_10_77.swi) and hit eXecute.
    3139 * Set the hostname
    3240{{{
    3341hostname cafiero
     42}}}
     43 * Disable the telnet and web interface:
     44{{{
     45configure
     46no telnet-server
     47no web-management
     48}}}
     49 * For the switch in XO that connects to Highwinds, we have to disable auto-negotiation, and force it to use a 100Mbit connection to avoid dropped packets. The 1 refers to port one on the switch, which presumably the upstream is connected to.
     50{{{
     51configure
     52interface 1 speed-duplex 100-full
    3453}}}
    3554