    33We have a [http://www.hp.com/rnd/support/manuals/2800.htm HP Procurve 2824 switch] at both Telehouse and XO. We have the [/attachment/ticket/4278/hp2824-manual.pdf manual available].
    44
    5 Start by resetting to factory defaults.
     5== Reset to factory defaults and set serial console ==
    66
    7 Do that by poking a staple in both the reset and clear buttons and then
    8 releasing the reset button and keeping the clear button pressed. That may leave
    9 the switch in a state with all lights on. If so try unplugging and plugging it back in.
     7Do that by poking a staple in both the reset and clear buttons and then releasing the reset button and keeping the clear button pressed. That may leave the switch in a state with all lights on. If so try unplugging and plugging it back in.
    108
    119Next, try to access it via the serial console at 2400 baud.
     
    2523
    2624After it restarts, you should re-connect via the new serial console settings
    27  * At this point, you might want to upgrade the firmware. Check the [http://h17007.www1.hp.com/us/en/support/converter/index.aspx?productNum=J4903A HP page for the latest firmware]. Check the running firmware with:
     25
     26== Upgrade Firmware ==
     27
     28 * Check the [http://h17007.www1.hp.com/us/en/support/converter/index.aspx?productNum=J4903A HP page for the latest firmware]. Check the running firmware with:
    2829{{{
    2930show version
    3031}}}
     32
    3133As for 2012-11-3, the latest firmware on the site is i.10.77 built on 26-Aug-2009, posted on 26-Oct-2009.
     34
    3235 * To update the firmware:
    3336  * Downloading the latest version to a machine connected to the switch
     
    4144hostname cafiero
    4245}}}
     46
     47== Harden the switch ==
     48
    4349 * Disable the telnet and web interface:
    4450{{{
     
    5359snmpv3 only
    5460}}}
    55  * For the switch in XO that connects to Highwinds, we have to disable auto-negotiation, and force it to use a 100Mbit connection to avoid dropped packets. The 1 refers to port one on the switch, which presumably the upstream is connected to.
    56 {{{
    57 configure
    58 interface 1 speed-duplex 100-full
    59 }}}
    6061
     62 
    6163[[TicketQuery(keywords=~hp-procurve,format=table,col=resolution|summary)]]